Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower

Product Details
Customization: Available
After-sales Service: Free Consultation
Warranty: 12months
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (15)
  • Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
  • Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
  • Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
  • Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
  • Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
  • Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Find Similar Products
  • Overview
  • Product Description
  • Other Products
Overview

Basic Info.

Model NO.
Closed Water Cooling Tower
Cooling Method
Counter Flow
Ventilation Mode
Natural Ventilation
Material
Metal
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industrial
Certification
CE, SGS
Condition
New
Installation Instruction
Include
Factory
Yes
OEM Label
Agree
Temperature Control
Yes
Install
Manufacturer-Guided Installation
Other Name
Shot Blasting Machine
to Customer
Just Tell Us What You Want
Transport Package
as Requirement
Specification
as requirement
Trademark
RUNHAI
Origin
China
HS Code
8514200
Production Capacity
5000

Product Description

Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Product Description

 

Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower

Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower  
          The winter temperature in the northern region is usually below zero, and the operation of the closed cooling tower anti-freezing problem is becoming increasingly prominent, if it is not solved well, it may freeze the heat exchange tube or other components of the cooling tower. According to different process characteristics, some closed cooling towers run all day in winter, some run for part of the time, and some are almost not used. But all need to consider the problem of frost protection.

We main make customized production according to customer requirements:
1.Just tell us your own demands;
2.Designed according your requirements,send you drawing;
3.Modify a detail;
4.production according drawing;
5.Delivery on time;
6.Technical personnel guide the installation.
7.Any question we provide 24-hour service consultation.
8.Warranty for 24 months.
9.Free consultation for life

 

Working principle of closed water tower

1, the closed cooling tower is actually an evaporative cooling tower, a combination of coolers and wet cooling towers, it is a horizontal evaporative cooling tower, the process fluid flows in the tube, the air flows in the tube, the two do not touch each other. Closed cooling tower is a kind of deformation and development of traditional cooling tower. After the water in the reservoir at the bottom of the tower is extracted by the circulating pump, it is sent to the outside of the pipe and sprayed down evenly. It is not in contact with the process fluid hot water or refrigerant and the air outside the pipe, and becomes a closed cooling tower, which enhances the heat and mass transfer effect by spraying water.

2, closed cooling tower is suitable for a variety of cooling systems with high circulating water quality requirements, and has application prospects in power, chemical, steel, food and many industrial sectors. On the other hand, compared with the air-cooled heat exchanger, the evaporative cooling tower makes use of the latent heat of the water on the lower side of the pipe to significantly enhance the heat and mass transfer on the air side, and also has obvious advantages.

Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower

Other Common type size:

 

Anti-freezing measures in each scenario

The winter temperature in the northern region is usually below zero, and the operation of the closed cooling tower anti-freezing problem is becoming increasingly prominent, if it is not solved well, it may freeze the heat exchange tube or other components of the cooling tower. According to different process characteristics, some closed cooling towers run all day in winter, some run for part of the time, and some are almost not used. But all need to consider the problem of frost protection.

Winter basically not use the occasion

If the closed cooling tower does not need to run in winter, the spray water and internal circulating water must be emptied when it is shut down. The internal circulating water is recommended to be forced to use compressed air with a pressure greater than 4 kg, and the carbon steel tube heat exchanger is not recommended to use the way of emptying to prevent freezing. Scenarios that run in partial time

The antifreeze of the closed cooling tower has two parts: the spray water system and the internal circulating water system (softened water).

The antifreeze problem of the spray water system is usually added to the electric heater in the water tray, which is generally opened when the spray water is below 5 ° C and stopped above 8 ° C. The temperature probe transmits the signal to the control cabinet to automatically control the start and stop of the electric heater. The power selection of the electric heater is determined according to the circulating water volume and the external temperature.

The antifreeze of the internal circulating water system can be added with glycol solution or electric heating equipment. The freezing temperature of the glycol solution must be lower than the local lowest temperature.

For large cooling system occasions, you can consider digging a pool to spray water into it, which can save the power consumption cost of electric heating operation, and can also put drugs in the pool to improve the water quality of the spray water.

The problem of frost prevention in the occasions of perennial operation

The closed cooling tower running all year round, if equipped with an electronic control system, may change the number of cooling tower operation due to the load change of the main system, so it is also necessary to consider the problem of antifreeze. Unused equipment can be emptied before winter to prevent freezing.

With the continuous development of science and technology, closed cooling towers will inevitably usher in greater development and application space.

 

Closed cooling tower product features

1.Improve production efficiency, soften water circulation, no scaling, no blockage, no loss;

2.Extend the life of the equipment, ensure the reliable and stable operation of the equipment, reduce failures and eliminate accidents;

3.Fully closed cycle, no impurities entering, no medium evaporation, no pollution;

4.Improve the utilization coefficient of the plant, no need for the pool, reduce the area and save space;

5.Small space, convenient installation, movement, layout, compact structure;

6.Easy to operate, stable operation, high degree of automation

7.Save operating costs, automatic switching of multiple modes, intelligent control:

8.Widely used, non-corrosive medium for heat exchangers, can be directly cooled, low life operating cost, high initial investment, low operation and maintenance costs.

Model

Size (L * W * H)

Fan power(kw) Main pump(kw) Spray pump power Flow ratem³/h
10T 2250*900*2300 0.37 2.2 1.1 10
15T 2250*900*2500 0.37 3 1.1 15
20T 3000*900*2300 0.37 4 1.5 20
30T 3000*900*2500 0.75×2 4 1.1 30
40T 3000*1150*2500 0.75×2 5.5 1.5 40
50T 2800*1150*2600 1.1×2 5.5 1.5 50
60T 2800*1150*2800 1.5×2 7.5 2.2 60
80T 2800*1430*2800 2.2×2 7.5 2.2 80
100T 3400*1430*2800 1.5×3 11 2.2 100
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
 
 
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
 
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower

 

Customized OEM Big Flow Rate Closed Counter Flow Water Cooling TowerShandong Runhai Machinery Technology Co., Ltd. registered capital of 10 million, the existing staff of 25 people, technical personnel 6 people, the factory covers an area of 3200 square meters, the annual production capacity of 50 million yuan, located in Weifang City, Shandong Province, the products involved in steel and metallurgy, aerospace, military medical, automotive and other fields.

The company actively carries out the development of scientific research projects, and introduces and absorbs the advanced technology of European and American countries, has accumulated rich experience in design and manufacturing, and has trained a strong technical research and development team and after-sales service guarantee team. The company's products are exported to Australia, Russia, Mexico, Hungary, Turkey, India, Malaysia, Indonesia, Thailand, Morocco nearly 20 countries and regions, has been praised by domestic and foreign customers.

The company's main products are: truck annealing furnace, forklift quenching furnace, tempering furnace, carburizing furnace, nitriding furnace, vacuum furnace, mold shell baking furnace, medium frequency furnace, precision casting equipment, sand casting equipment, shot blasting machine, cooling tower and other products.
The company always adheres to the purpose of quality first and customer first, and is willing to meet the needs of market competition and international economic globalization with high-quality products, reliable commitment and first-class service.
Other Products

 

Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower
Customized OEM Big Flow Rate Closed Counter Flow Water Cooling TowerCustomized OEM Big Flow Rate Closed Counter Flow Water Cooling Tower

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier